Welcome to our community! Hello Experts! The problem i want to fix is the looooooooong time i have to wait at startup, above 60 seconds, while the computer takes or not the IP address on a not-dhcp server enviroment.

I have seen there are some post regarding the solution, but as im not a premiere user, i cannot see the answers. Can anyone tell me how to change this client DHCP timeout issue?

Join our community to see this answer! Unlock 1 Answer and 16 Comments. Thank you! Any more feedback? The more you tell us the more we can help. Can you help us improve? Resolved my issue. Clear instructions. Easy to follow. No jargon. I don't think I even changed anything - the problem seemed to come out of nowhere. It looked like the setting was on 1. I'm trying that to see if it helps. I too don't want to change a setting on the Windows server if I can help it.

It's been working for years as it is. The last change we made that we are cautiously optimistic about was splitting the 5 and 2. The only reason I haven't posted back is that I did not want to spread bad info. It's a shame we can't use combined SSID but so far this appears to be working.

I updated to the latest firmware on the cloud key Rev 2. Also the DITM setting to 3 resolved the issue immediately for me. This mostly affected the Apple devices in our environment. Where we are sitting right now, it looks more and more like the issue is caused by how Unifi handles band steering. We disabled the "advanced features" on the cloud key but the issues continued. By separating the 2. To continue this discussion, please ask a new question.

Which of the following retains the information it's storing when the system power is turned off? Submit ». Get answers from your peers along with millions of IT pros who visit Spiceworks. Otherwise, wait for resynchronization to complete before returning.

This is used for compatibility purposes. The default is 2 seconds. If not specified, the default is the local computer. When specifying multiple peers, this option must be enclosed in quotes. This setting is only meaningful on domain controllers. YES : This computer is a reliable time service. NO : This computer is not a reliable time service. If not specified, the default value is the local computer. In verbose mode, display the undefined or unused setting too.

Valid values are 0 to A range of numbers is valid, in addition to single numbers, such as ,, Value is for logging all information. Set client to use two time servers To set a client computer to point to two different time servers, one named ntpserver. To configure a client computer that is currently synchronizing time using a manually-specified computer to synchronize time automatically from the AD domain hierarchy, run the following following:.

To check a client configuration from a Windows-based client computer that has a host name of contosoW1 , run the following command:. The output of this command displays a list of W32time configuration parameters that are set for the client. Windows Server has improved the time synchronization algorithms to align with RFC specifications. Therefore, if you want to set the local time client to point to multiple peers, we recommended that you prepare three or more different time servers.

If you have only two time servers, you should specify the Ntpserver UseAsFallbackOnly flag 0x2 to de-prioritize one of them. For example, if you want to prioritize ntpserver. Additionally, you can run the following command and read the value of NtpServer in the output:. In order for W32tm. Then, to adjust the computer clock by using the clock rate, W32tm. This algorithm varies depending on the version of Windows:. MaxAllowedPhaseOffset is configurable in the registry.

However, the registry parameter is measured in seconds instead of clock ticks. This command produces output that resembles the following. The output presents the poll interval in both clock ticks and in seconds.

The equations use the value measured in seconds the value in parentheses. The output presents the clock rate in seconds. To see the SystemClockRate value in clock ticks, use the following formula:. For example, if SystemClockRate is 0. For full descriptions of the configurable parameters and their default values, see Config entries later in this article.

The following examples show how to apply these calculations for Windows Server R2 and earlier versions. In this case, if you want to set the clock back slowly, you would also have to adjust the values of PhaseCorrectRate or UpdateInterval in the registry to make sure that the equation result is TRUE. The Windows Time service stores a number of configuration properties as registry entries. It stores configuration information that the policies define in the Windows registry, and then uses those registry entries to configure the registry entries specific to the Windows Time service.

As a result, the values defined by Group Policy overwrite any pre-existing values in the Windows Time service section of the registry. Some of the preset GPO settings differ from the corresponding default Windows Time service registry entries. Windows loads these settings into the policy area of the registry under the following subkey:. Then Windows uses the policy settings to configure the related Windows Time service registry entries under the following subkey:.

The following table lists the policies that you can configure for the Windows Time service, and the registry subkeys that those policies affect. When you remove a Group Policy setting, Windows removes the corresponding entry from the policy area of the registry. This information is provided as a reference for use in troubleshooting and validation.

Windows registry keys are used by W32Time to store critical information. Don't change these values. Modifications to the registry are not validated by the registry editor or by Windows before they are applied. If the registry contains invalid values, Windows may experience unrecoverable errors. Some of the parameters in the registry are measured in clock ticks and some are measured in seconds.

To convert the time from clock ticks to seconds, use these conversion factors:. Note Zero is not a valid value for the FrequencyCorrectRate registry entry. HoldPeriod All versions Controls the period of time for which spike detection is disabled in order to bring the local clock into synchronization quickly.

A spike is a time sample indicating that time is off a number of seconds, and is usually received after good time samples have been returned consistently. The default value on domain members is 5.

The default value on stand-alone clients and servers is 5. LargePhaseOffset All versions Specifies that a time offset greater than or equal to this value in 10 -7 seconds is considered a spike. A network disruption such as a large amount of traffic might cause a spike.

A spike will be ignored unless it persists for a long period of time. The default value on domain members is The default value on stand-alone clients and servers is It contains reserved data that is used by the Windows operating system, and any changes to this setting can cause unpredictable results. MaxAllowedPhaseOffset All versions Specifies the maximum offset in seconds for which W32Time attempts to adjust the computer clock by using the clock rate.